What manufacturing data to collect, and how to collect it
Collect machine state, part counts, stop reasons and scrap first. See what sensors, controllers and operators each capture, and what to ask a vendor.
Ulises Carrasco, Co-founder and COO
9 min read
Updated : Rewrote the post with a data list, a vendor checklist and two figures.
The shop-floor data worth collecting first is four records per machine: when it runs and stops, how many parts it makes, why each stop happened and which parts were scrapped. When you evaluate a data collection system, ask which of those records it captures with no typing, how it reads machines of every age, and how you check and export what it records.
Owners and plant managers deciding where to start get three things here: what sensors, controllers and operators each capture, why paper logs undercount, and a checklist to take into a vendor call.
Key takeaways
- Start with four records on every machine: when it runs and stops, how many parts it makes, why it stopped and what was scrapped.
- A sensor records when a machine stopped and for how long, but only a person at the machine can record why.
- Paper logs miss short stops, so availability on paper reads higher than the machine’s real availability.
- Controller data adds alarms, programs and process values, and IT usually reviews that connection before it goes live.
- Ask a vendor which records arrive with no typing, how counts are validated and how you get every record back out.
What manufacturing data collection means#
Definition
Manufacturing data collection is the capture of what each machine and its operators did during a shift: when the machine ran and stopped, how many parts it made, why it stopped and which parts were scrapped, recorded with timestamps as each event happens.
The machine record sits at the bottom of every other system in the plant. ISA-95, the standard for connecting plant-floor systems to business systems, puts “the collection of data and the manipulation of physical processes” at Level 1, manufacturing execution systems (MES) at Level 3 and the activities of running the business, such as ERP, at Level 4.[1]
For example, an ERP that reports the cost of a job needs the machine hours that job used. If those hours come from an operator’s estimate at the end of the shift, the job cost inherits the estimate.
Why manual collection falls short#
Most plants already collect data, on paper travelers, whiteboards or a spreadsheet filled in at the end of the shift. Manual records fail in three ways:
- Short stops go unrecorded. Nobody writes down a two-minute jam, and a busy machine has many of them in one shift.
- Times are estimates. A stop logged as “about 20 minutes” at 3 p.m. was written from memory.
- The data arrives late. A sheet read the next morning can’t help the shift that produced it.
Minor stops are short interruptions, often a minute or two long, that operators clear without calling maintenance staff.[2] Vorne’s rule of thumb is to set the line between a minor stop and a logged stop by your policy for tracking reasons, for example a reason on any stop longer than two minutes.[2] Anything shorter rarely reaches a paper log.
Worked example
One shift on a CNC lathe, logged two ways
- Shift: 480 minutes, with a 30-minute break, so planned production time is 450 minutes.
- Sensor record: 17 stops. Three long ones (25, 18 and 12 minutes) add up to 55 minutes, and 14 short stops of 2 minutes add 28 more, for 83 minutes stopped.
- Paper log: the three long stops, 55 minutes.
Availability from the paper log is (450 − 55) ÷ 450 = 87.8%. Availability from the sensor record is (450 − 83) ÷ 450 = 81.6%. A third of the stopped time (28 of 83 minutes) never reached the paper.
The missing 28 minutes don’t vanish from your results. The paper log counts them as run time, and in OEE minor stops count as a performance loss, so the machine looks slow instead of stopped and nobody looks for the cause.[2] What is OEE? explains how the three factors split those losses.
What data is worth collecting#
Each record answers one question, and each has a natural source. Collect the first five on every machine before you add anything else; cycle time comes from the count at no extra cost.
| Record | Question it answers | Where it comes from |
|---|---|---|
| Machine state | When did it run, and how long did it stop? | Sensor or controller |
| Part count | How many parts, at what pace? | Sensor, laser counter or controller |
| Cycle time | How long does one part take? | Derived from the count |
| Stop reason | Why did it stop? | Operator, or an automatic rule |
| Scrap and its reason | How many were bad, and why? | Operator |
| Vibration and temperature | Is the machine wearing? | Sensor on the motor or spindle |
| Alarms and programs | What did the control see? | Controller connection |
| Job and order | What was it supposed to make? | ERP or the schedule |
Each role reads the same records at a different level:
- Operators need the count against the shift goal and the stops still waiting for a reason, at the machine.
- Plant managers need the fleet: which machines are down now, and which reasons cost the most hours this week.
- Engineers and maintenance need history: cycle times by part, the step that limits a line, and vibration trends on critical machines.
You don’t need vibration data on every machine. Add it where a breakdown stops a line or a repair costs days, for example on the spindle of the one 5-axis machining center that every job passes through.
Machine data and human context#
A machine record tells you when a machine stopped and for how long. It can’t tell you why. A spindle that sits still for 14 minutes looks the same in the data whether the operator was waiting for material, changing a tool or refilling coolant.
The reason comes from the person at the machine. A downtime category is a reason code an operator puts on a stop, such as Tool change or Waiting for material; the glossary entry lists what each one carries. The best stop record combines all three sources: the time from the sensor, the alarm from the controller where one is connected, and the reason from the operator.
Reasons pay off over weeks, not on the day. Datwyler’s injection molding plant found that “Tuesday shift transitions turned out to add 8 to 10 minutes of downtime, every week”, a pattern that showed up week over week once every stop carried a reason. The Datwyler story shows how three automatic rules classify routine stops and operators classify the rest.
Keep the reason list short enough to fit on one screen. An operator facing a long list picks whatever sits at the top.
Three ways to get data off a machine#
You can read a machine from the outside with a sensor, from the inside through its controller, or by having a person write it down. Most plants combine at least two.
| External sensor | Controller connection | Manual entry | |
|---|---|---|---|
| Works on any machine age | Yes | No | Yes |
| Needs access to the control | No | Yes | No |
| Records short stops | Yes | Yes | No |
| Records why it stopped | No | No | Yes |
| Reads alarms and programs | No | Yes | No |
| Usual IT review | Network access only | The controller connection | None |
An external sensor reads vibration, sound or a passing part, and decides from that signal whether the machine is running. It works the same on a 1985 manual-load lathe and a new machining center, because it never touches the control.
A controller connection reads what the control already knows, over standards such as MTConnect for CNC machines and OPC UA. OPC UA, released in 2008, includes message encryption, message signing and certificate-based authentication.[3]
Even so, a connection to a PLC or CNC control is a security concern for many plants, and IT usually reviews it first. Sensor-based vs PLC machine monitoring compares what each method sees, signal by signal.
How often to record#
Record machine state as events, not snapshots. A state change event is a record written the moment a machine starts or stops, with its timestamp.
For example, a system that polls a machine every 15 minutes sees “running” at 10:30 and at 10:45, and misses a 9-minute stop in between. An event log records the stop at 10:34 and the restart at 10:43.
Ask where and how the running-or-stopped decision is made. A device that decides on the machine, every second, against settings fixed at calibration catches the stops a poll misses; how IoTFlows works shows that path for one system. Every metric downstream is built from that stream, so ask how calibration is checked too.
Counts and scrap can then be summed by hour or by shift from the same events. Vibration for machine health is the exception: a vibration spectrum is computed from the raw signal, sampled far faster than any state change.
A buyer’s checklist for a data collection system#
Take these questions into a vendor call. The right column is what a good answer sounds like.
| Question to ask | A good answer |
|---|---|
| Which records arrive with no typing? | State, counts and stop times |
| Does it work on our oldest machine? | Yes, with no wiring into the control |
| Where is running or stopped decided? | On the device, from calibrated settings |
| How does an operator add a reason? | One tap, at the machine or on a phone |
| How are part counts validated? | Against a hand count of ten parts |
| What does IT need to approve? | HTTPS on port 443, or a cellular router |
| Does it connect to controllers? | Only the ones you choose to connect |
| Which systems does it feed? | ERP, CMMS and chat, both ways if needed |
| Can we get the raw records out? | CSV export and an API |
| How long until the first data? | The same day for the first machine |
Leave out questions about features the machine record doesn’t need. Payroll rules, supplier scoring and demand forecasting belong to other systems; a data collection system should feed them, not replace them.
Collect machine data automatically#
IoTFlows records state, part counts and stop times with a sensor on each machine, and operators add reasons and scrap. A SenseAi attaches with a magnet, reads vibration and sound from the outside and decides running or stopped every second on the device, with no PLC connection. Part counts and cycle times come from the same signal.
Operators classify a stop in a tap at the machine, in Operator View or in the iOS app, and automatic rules classify routine ones such as short stops and shift starts.
On Enterprise, the IoTFlows edge device brings in PLC, robot and CNC data through custom integrations, and reads only the controls you choose to connect. MiRus runs a two-way Epicor connector that ties every job to the machining and labor hours behind it, and the connector went live in about a month.
Where to start#
Pick one area
Start with the machines that limit output, not the whole plant. The rollout plan walks through a first line, then operator adoption, then reasons.
Set shifts before you read any number
Every figure is bucketed by shift as it arrives, so set the timezone and shifts first.
Write a short reason list
Give operators reasons they can choose in a tap, grouped by how much each costs.
Validate the count
Run ten parts, count them by hand and compare. The production quickstart walks through the check.
Review stops every week
Rank reasons by the hours they cost with a downtime Pareto, fix the top one, and check the next week whether it shrank.
Questions#
Do I need to connect to the PLC to collect machine data?#
No. A sensor mounted on the outside of a machine records running and stopped time, part counts and vibration with no access to the control. Connect to the controller when you need data only it holds, such as alarm codes, the active program or spindle load, and plan for an IT review of that connection.
How often should machine data be recorded?#
Record machine state as events with timestamps, not as periodic snapshots. A reading taken every 15 minutes cannot see a two-minute stop, while a state change logged the second it happens catches every stop. Counts and scrap can then be summed by hour or by shift from the same record.
How is data collection different from an MES?#
Data collection captures what happened at each machine: state, counts, reasons and scrap. An MES uses records like these to manage production orders, routings and execution across the plant. Collect machine data first when you don’t yet know how your machines run, because every MES function depends on an accurate machine record.
Can operators still log data by hand?#
Yes, and they should for the things only they know: the reason for a stop, the cause of a scrapped part and notes for the next shift. What changes is that the machine records the time and duration of each stop on its own, so the operator adds the reason instead of writing down the clock.
Written by
Ulises Carrasco, Co-founder and COO