Review and dismiss machine events
The event feed for one machine, and what to do with what it flags.
An event is the record IoTFlows writes when an alert rule on this machine fires: a health score falling past 60%, a stop longer than your downtime threshold, a shock above the sensor's g limit. The rule decides when that happens and who gets told. The event is what the rule leaves behind, and the Event Alerts list on the Health tab is where you read it.
Prerequisites. A SenseAi or SenseAi Embedded asset on firmware 5 or later, see Monitor machine health and vibration. At least one event type enabled on the machine, see Set alert rules for a machine.
Open the event list
- Open the machine's page at
/assets/selected-asset/:id. - Click Health in the tab strip under the header.
- In the right column of the Machine Health Summary card, click Alerts.
That column holds two tabs, each with its own count: Alerts, the events, and Notes, the comments people have left on this machine's charts. The chip beside the Event Alerts heading repeats the total.
The list ignores the time range buttons at the top of the tab. Moving from 7d to 90d redraws every chart and leaves the list alone, because it is not a window: it is every event on this machine that nobody has dismissed yet. To dismiss an event is to mark it handled, which takes it off this list.
With nothing outstanding, the card reads No Active Alerts, over All systems operating normally.
The event list for one machine. Each row is a rule that fired.
Filter by severity and type
Two rows of pills sit above the list. Severity offers All, Critical, Warning and Caution, and Type offers All, Health, Temp, Machine and Shock. The two combine, so Critical plus Temp shows only critical temperature events.
The number on each pill counts the whole list, not what the other row leaves. Critical (4) still reads 4 with Health selected, even when only one of those four critical events is a health event.
Device Offline events count as Machine. Type is read from the event type's own name, and a lost connection carries none of the four, so it falls in with Machine Down and Machine Up.
Filter before you clear anything. The bulk action described in Dismiss a whole group acts on what the filters leave visible, which makes "clear every caution and keep the criticals" two clicks.
Filtering the feed by severity and event type.
Read an event
Every row carries the same six things:
- A type icon: a heart for health, a thermometer for temperature, a falling clock for machine status, a waveform for shock.
- The event title, for example Warning Health Alert or Machine Down.
- The measured value, in a pill colored by severity, with the unit the event type implies:
%for a health score,°Cfor temperature,Gfor shock,minfor a stop. - How long ago it fired, written as
22m ago,6h ago,Yesterdayor3d ago. - The one-line message the event type carries.
- A Dismiss link.
Rows are grouped by age under Last 15 min, Last hour, Last 6 hours, Last 24 hours and Older. A group with no events is not drawn at all. Inside a group, critical sorts above warning above caution, and newer above older within one severity.
A group of three events or fewer is drawn flat. A group with more than three collapses into a stack of three cards under a header carrying the count. Click the header to expand it.
Click a row to line every chart on the tab up on the moment the event fired, and a panel headed Existing at this time lists the notes and events within five minutes of it. In a collapsed stack the first click expands the group instead, so expand the group, then click the row. See the timestamp inspector.
Why does a temperature event read °C when I set the rule in °F? The value pill is always Celsius. The threshold on the rule follows your unit preference, the event does not.
Event severities
| Severity | Color | Typically from |
|---|---|---|
| Critical | Red | Critical Health Alert, which fires below 20%. Critical Temperature. Machine Down at its critical threshold |
| Warning | Amber | Warning Health Alert, which fires below 40%. Warning Temperature. Machine Down at its warning threshold |
| Caution | Yellow | Caution Health Alert, which fires below 60%. Also the fallback: an event arriving with no severity of its own is shown as a caution |
Severity belongs to the event type, not to the event, so you cannot raise or lower one row. It sets the row's color, its position in the group, and which severity pill counts it. Which event types exist and what each one fires on is in Event types reference.
Dismiss one event
Click Dismiss at the right of the row. The row leaves immediately and a toast reads Event has been dismissed.
Dismissing sets a flag on the event rather than deleting it, so the record survives. No view in the dashboard shows dismissed events, so treat dismissal as the end of your involvement with that row, not as a way to find it again next week.
Dismiss an event when you have decided about it, not to clear the list. Clearing the list unread every morning trains everyone to skip the next one, and the next one is the bearing that gave four weeks of warning.
Dismiss a whole group
Dismiss All appears on a group's header, and only on a group holding more than three events. A group of three or fewer has no header, so those rows are dismissed one at a time.
- Set the severity and type filters to the events you mean to clear.
- Click the group header, for example Last 24 hours, to expand it.
- Click Dismiss All.
It dismisses the events the filters leave visible in that group, not the whole list. With Caution selected, the criticals in the same group stay. A toast reports the count, for example 12 events dismissed.
Use Dismiss All on a group that is one incident repeated: forty shock events from one crash, or a run of Machine Down rows from a shift everybody already knows about. Dismiss one at a time when the group is mixed, because one bulk click takes the row you had not read yet along with the thirty-nine you had.
Dismiss All clears one time group, and only the events the filters leave visible.
Turn an event into work
No button on an event row opens a work order. Two routes exist instead, and they answer different questions.
Have the rule open it. Every event type on a machine carries a Work Order column in Event Notifications, with a member to assign the work order to. Turn it on and each event of that type arrives on the maintenance board with nobody having to notice it. Set this up in Set alert rules for a machine.
Open one yourself. For an event you read and decided about, raise the work order by hand so you can write what you actually saw into it, see Create a work order.
You do not need the automatic work order on every event type. Turn it on for events with one obvious response, such as a critical health alert. Leave it off for Machine Down and Device Offline, which fire often and usually mean a person, a jam or a network, not a repair.
Errors
| Symptom | Cause | Do this |
|---|---|---|
| Failed to dismiss event | The dismissal did not save, and the row comes back when the list reloads | Retry. The event is unchanged |
| Failed to dismiss events | The same, for Dismiss All. None of the group was dismissed | Retry, or dismiss the rows one at a time |
| The list is empty while the machine is clearly in trouble | No event type is enabled for what is happening, or the event type is enabled to notify but not to log | Open Event Notifications and check the rule and its Log switch, see Set alert rules for a machine |
| No Alerts card anywhere on the tab | The asset is on firmware below 5 and shows the legacy health view | Ask IoTFlows to update the device, see Get support |
| A BeamTracker machine has no list at all | A BeamTracker has no Health tab, and the list lives on that tab | Read its events from the notifications they send. See Set alert rules for a machine |
See also
Set the reference a machine's health scores are judged against on the Health tab: Dynamic Baseline, four ISO 10816 classes, or one of eight machine-type profiles, which profile fits which machine, and what the confirm dialog recalculates.
The Advanced Report totals uptime, downtime and unknown hours for a set of machines over a period, as KPI cards, a stacked bar per interval, a pie and a row per machine grouped by department. Pick a rolling preset or a custom range at a daily to yearly interval, filter by machine and shift, exclude Unknown and None from the utilization figure, switch to only-uptime or percent view, and export the result as CSV or PDF.